SCHRACK General Purpose Relays Interface Plug-in Relay XT n 1 pole 16 A, 2 pole 8 A, 1 CO contact or 2 CO contacts n DC- or AC coil, sensitive coil 400 mW n Reinforced insulation, protection class II (VDE 0700) n 4 kV / 8 mm coil-contact n Manual test tab, optionally lockable1) n Version with mechanical and/or electrical indicator optionally available n Suitable for use in Tyco standard RT sockets n Recycleable packaging F0289-B Applications Panel boards, mechanical engineering Approvals V REG.-Nr. B758, Z E214025 Technical data of approved types on request Contact data 1-pole 2-pole Contact configuration 1 CO 2 CO Contact set single contact Type of interruption micro disconnection Rated voltage / max. switching voltage AC 240 / 400 VAC Rated current 16 A 8A Limiting continuous current 16 A 8 A, UL: 10 A Maximum breaking capacity AC 4000 VA 2000 VA Limiting making capacity,max 4 s, df 10% 30 A 15 A Contact material AgNi 90/10 Rated frequency of operation with / without load 6 / 600 min-1 Operate- / release time DC coil max 8 / 6 ms max 10 / 5 ms Bounce time DC coil, NO / NC contact max 4 / 6 ms max 4 / 9 ms Contact ratings Type ContactLoad IEC 61810 XT3 XT3 XT4 XT4 DC-coil UL 508 XT3 XT4 XT4 Ambient temp. [C] Cycles CO NO CO NO 16 A, 250 VAC, cos=1 16 A, 250 VAC, cos=1 8 A, 250 VAC, cos=1 8 A, 250 VAC, cos=1 70C 70C 70C 70C 30x103 50x103 50x103 100x103 CO CO CO 16 A, 250 VAC, general purpose 10 A, 250 VAC, general purpose 8 A, 250 VAC, general purpose 70C 70C 70C 30x103 20x103 30x103 Coil data Rated coil voltage range DC coil AC coil Operative range to IEC 61810 Coil insulation system according UL1446 6...110 VDC 24...230 VAC 2 class F 1) Locking function description If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position. Delivery status is with testing possibility only, to reach locking position please remove the locking plastic pip according drawing. 1 Datasheet Rev. IJ1 Issued 2009/10 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' section in the catalogue or at schrackrelays.com in the `Schrack' section. Specifications subject to change. SCHRACK General Purpose Relays Interface Plug-in Relay XT (Continued) Coil versions, DC-coil Coil LED & Rated Operate Release Coil Rated coil opt. LED code PD* voltage voltage voltage resistance power power VDC VDC VDC Ohm mW mW 012 LB2 12 8.4 1.2 360+10% 400 10 024 LC4 24 16.8 2.4 1440+10% 400 19 048 LE8 48 33.6 4.8 5520+10% 417 39 110 MB0 110 77.0 11.0 28800+12% 420 87 All figures are given for coil without preenergization, at ambient temperature +23C *) Protection diode PD; standard polarity: +A1 / -A2 Other coil voltages on request Coil versions, AC-coil Coil LED Rated code voltage Operate Release Coil Rated coil opt. LED voltage voltage resistance power power 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz VAC VAC VAC Ohm VA VA 524 R24 24 18.0 / 19.2 3.6 350+10% 0.76 / 0.58 0.012 615 S15 115 86.3 / 92.0 17.3 8100+15% 0.76 / 0.58 0.054 730 T30 230 172.5 / 184.0 34.5 32500+15% 0.74 / 0.58 0.073 All figures are given for coil without preenergization, at ambient temperature +23C Other coil voltages on request Insulation Dielectric strength coil-contact circuit 5000 Vrms in combination with RT78726 4000 Vrms in combination with RT78725 1000 Vrms 2500 Vrms W 8 / 8 mm IIIa PTI 175 V open contact circuit adjacent contact circuits Clearance / creepage coil-contact circuit Material group of insulation parts Tracking index of relay base Insulation to IEC 60664-1 Type of insulation coil-contact circuit open contact circuit adjacent contact circuits Rated insulation voltage Pollution degree Rated voltage system Overvoltage category reinforced micro disconnection basic 250 V 3 2 240 V 230 / 400 V III Terminal assignment Bottom view on pins 1 CO contact 16 A S0163-BE Other data 1-pole 2-pole Mechanical endurance DC coil > 10 x 106 AC coil > 5 x 106 Material RoHS - Directive 2002/95/EC compliant Environment Ambient temperature range DC coil -40...+70C AC coil -40...+70C Vibration resistance (function), NO / NC cont. 20 / 5 g, 30 ... 500 Hz Shock resistance (destruction) 100 g Category of protection RTII Processing Mounting distance W 4,5 mm, dense packing of sockets Relay weight 16 g Packaging unit 10 / 250 pcs 2 CO contacts 8 A S0163-BJ s0538_BB Dimensions Accessories For Details see datasheet NOTE: Accessories Interface Power Relay XT indicated contact ratings and electrical endurance data for direct wiring of relays (according IEC 61810-1, table 12); for relays mounted on sockets deratings may apply. S0538_B 2 Datasheet Rev. IJ1 Issued 2009/10 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' section in the catalogue or at schrackrelays.com in the `Schrack' section. Specifications subject to change. SCHRACK General Purpose Relays Interface Plug-in Relay XT (Continued) Product key Typical product key XT 3 7 4 T30 Type XT Interface Plug-in Relay XT Version 3 1-pole, 16 A, pinning 5 mm 4 2-pole, 8 A, pinning 5 mm Contact configuration 1 1 CO contact (1 form C) 7 1 CO contact (1 form C) with test button and mechanical indicator 2 2 CO contacts (2 form C) 8 2 CO contacts (2 form C)with test button and mechanical indicator Contact material 4 AgNi 90/10 Coil Coil code: please refer to coil versions table, preferred types in bold print Product key XT374LC4 XT374R24 XT374T30 XT484LC4 XT484R24 XT484T30 Contacts 1 CO contact 16 A 2 CO contacts 8A Cont. material AgNi 90/10 test button, mechanical and electrical indicator Coil DC-coil AC-coil DC-coil AC-coil Coil 24 VDC 24 VAC 230 VAC 24 VDC 24 VAC 230 VAC Part number 1887112-1 1887113-3 1887113-1 1887212-1 1887213-3 1887213-1 3 Datasheet Rev. IJ1 Issued 2009/10 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' section in the catalogue or at schrackrelays.com in the `Schrack' section. Specifications subject to change.